Renomowanej firmy Labtex
Specifications:
Model | LTS-AAS3624 | LTS-AAS3628 | |
Optics System | Type | Single Beam | |
Monochromator | Anaberration C-T type, focal length 350mm | ||
Dispersing element | optical grating 1800 bars /mm, flicker wavelength 250nm | ||
Spectral bandwidth (nm) | 0.1、0.2、0.4、0.7、1.4、2nm six grades automatic switchover | ||
Wavelength range (nm) | 185-900nm | ||
Wavelength indication error | ±0.3 nm | ±0.2 nm | |
Wavelength repeatability (nm) | ≤0.1nm | ||
Spectral bandwidth deviation | ±0.02 nm | ||
Light point | 4 | 8 | |
Element lamp type | Ordinary element lamp | ||
Photometric Property | Reading mode | Transmittance, absorbance, concentration | |
Photometric Range | 0-125%,-0.1-3.00A | ||
Cu static baseline drift | ±0.004A/30min | ±0.003A/30min | |
Cu dynamic baseline shift | ±0.006A/15min | ±0.005A/15min | |
Background correction | Deuterium lamp background correction capability >= 30x (1Abs) | Deuterium lamp >= 40x (1Abs) | |
Graphite Furnace Analysis | Characteristic concentration | Cd ≤0.9pg Cu≤20pg | Cd≤0.6pg Cu≤20pg |
Detection Limit | Cd≤1.5pg Cu ≤25pg | Cd≤1.0pg Cu≤25pg | |
Repeatability(Cd) | RSD≤4% | RSD≤3% | |
Graphite furnace temperature range | Room temperature ~ 3000℃ | ||
Large power temperature rise range | 1500℃~3000℃ | ||
Slope and hold time | 1s~255s | 1s~255s | |
Heating rate | Maximum heating rate 2000℃/ s | ||
Atomization heating method | Light-controlled heating, time-controlled heating, general heating | ||
Outside protective gas flow | 1 L/min | ||
Tube protection gas flow | 4 adjustable levels (0, 50, 200, 250ml/min flow) | ||
safety precautions | Cooling water flow, protective gas pressure, furnace body temperature, power supply temperature, graphite tube installation alarm | ||
Data processing | Measurement mode | Graphite furnace process | |
Concentration calculation method | Standard curve method (6 linear and nonlinear fitting methods), standard addition method, interpolation method | ||
Number of repeated measurements | 1-30 times, calculate and give the mean, standard deviation and relative standard deviation of absorbance and concentration | ||
Report printing | Parameter printing, data result printing | ||
Others | Computer | circumscribed | |
Overall dimensions | 830*650*560 | ||
Weight | 110Kg | ||
Power | Voltage 220V±22V, frequency 50Hz ±1Hz | ||
Operating temperature | 10℃~30℃ | ||
Operating Humidity | 40%~85% |
Features
1. Excellent total reflection optical system ensures excellent signal-to-noise ratio of the instrument.
2. Comprehensive and safe intelligent gas control module.
3. Excellent full-band deuterium lamp background correction technology and high-performance self-priming dual background
correction.
4. Fully automatic instrument control, the light source supports high-performance element lamps, and can be quickly completed with one click.
5. Advanced eight-position lamp holder with 360-degree rotating design.
6. Novelly designed atomizer and intelligent lifting.
7. Simple, professional, automatic and fully operational RG-WinAAS workstation software under MS Window system.
Pomożemy w wyborze odpowiedniego inkubatora i odpowiemy na wszelkie nurtujące pytania.